Description
Clinically Validated
HM-ST30 auto BiPAP therapy device is tested to meet rigorous standards designed with 5 modes of ventilation – S, T, ST, Auto-S, and CPAP, inspiratory pressure from 4 cm H2O to 30 cm H2O.
Resistance Silencing Technology, No Sound Abatement Foam
No risk of aging particles accumulating in the airway. (Patented)
Special Air Filter
Effectively captures the minimum PM 0.2 viruses, bacteria, and aerosol. (Patented)
Integrated Auto-heated Tube
Anti-condensation water beads, high-temperature disinfection.
Automatically adjusts heating between 16-30°C.
Automatic Ramp Time
Gradually raise the pressure to the prescribed level once the user is asleep, more comfortable.
ST Mode Conversion
For most of sleep apnea, COPD,
or neuromuscular disorders.
- The ST mode seamlessly switches between Spontaneous (S) and Timed (T) modes based on the patient’s breathing activity.
- When the patient breathes independently, it operates in S mode, supporting each breath.
- If spontaneous breathing stops, the device automatically shifts to T mode to ensure continuous support.
- Once breathing resumes, it returns to S mode, adapting fluidly to the patient's needs.
Easy Pop-up Design
Built-in water tank for safety and stability.
Single eject button, effortlessly pop-up or put in.
Auto Start-stop Function
Treatment begins as soon as the mask is worn; the ventilator automatically stops a few seconds after mask removal.
Auto-adjust Temperature & Humidity
The intelligent system adjusts humidity based on ambient temperature and humidity, with a default setting at 2-3 levels.
Events Alarm for Your Attention
-
Suffocation alarm:
Turn on the suffocation, and the ventilator will notify you at the set time. -
High leakage alarm:
Turn on the high leakage, and the ventilator will notify the patient if high leakage is detected. -
Mask blockage alarm:
Turn on the mask blockage, and the ventilator will notify you immediately if any obstruction in the mask is detected. -
Humidifier waterless alarm:
Turn on the humidifier waterless, and if the humidifier runs out of water, the ventilator will alert the user.
Accurate Events Detection
Forced Oscillation Technique (FOT), cardiogenic fluctuations, and respiratory envelope analysis for accurate detection of central and obstructive respiratory events. (Patented)
IForced Oscillation Technique(FOT)
A non-invasive method to assess airway function by emitting oscillatory signals into the respiratory tract during tidal ventilation.
Cardiogenic Fluctuation
Small waves from heartbeats that appear on airway pressure and flow signals, helping to distinguish between central and obstructive apnea.
Respiratory Envelope Analysis Technology
This innovative method evaluates OSA severity without the need for manual scoring or traditional event scoring rules.
Accurate Events Detection
Forced Oscillation Technique (FOT), cardiogenic fluctuations, and respiratory envelope analysis for accurate detection of central and obstructive respiratory events. (Patented)